Preamble
P.B.anicut system is an old medium irrigation project constructed
across Paleru river in Paleru basin in Prakasam District in the year 1962.The anicut is intended for diversion of water through
right side main supply channel providing irrigation facilities to an extent of 7,318Ac under 9 system tanks in 9 villages of
Jarugumalli & Singarayakonda Mandals of Prakasam district.
Salient Features
Location |
: |
Singarayakonda(V), Singarayakonda(M) |
Registered Ayacut |
: |
7,318 Acres |
I.P Utilized during 2013-14 |
: |
4,200 Acres |
Mandals Benefited |
: |
Jarugumalli, Singarayakonda |
Water Utilisation |
: |
1219.00 Mcft |
Water allocation (Drinking) |
: |
Nil |
Water allocation(Industries) |
: |
Nil |
Cropping Pattern |
: |
Paddy |
Budget for the Year 2015-16 |
: |
Plan-0.3606 Crs |
Head Works |
Anicut |
Catchment area |
: |
2100Sqkm (811sqm) |
Length of Anicut |
: |
274.32 Mts.(Masonry) |
Top Level of Anicut (Crest) |
: |
+13.340 Mts. |
Designed Discharge |
: |
2464Cumecs. (87010 C/S) |
C Value |
: |
1000 |
M.F.L U/S |
: |
+16.210 Mts. |
M.F.L D/S |
: |
+15.000 Mts. |
Registered ayacut |
: |
7262 Acres |
Scour Sluice |
No. Of vents |
: |
4 Nos. |
Size of Vents |
: |
1.83 x 2.67 Mts. |
Sill Level |
: |
+10.21 Mts. |
Plat form Level |
: |
+17.37 Mts. |
Head Sluice |
Sill Level |
: |
+11.89 Mts. |
No. Of Vents |
: |
3 Nos |
Size of Vent |
: |
1.50 x 1.00 Mt. |
Platform Level |
: |
+19.81 Mts |
Discharge |
: |
140Cusecs |